CMCP-560 Isolated RTD Temperature
Transmitter |
|
 |
Features:
Approved
|
Description:
The CMCP-560 Isolated RTD Temperature
transmitters are compatible with isolated RTD inputs, they provide a 4-20 mA output proportional to the
overall measurement. Each unit provides power for the associated
transducer, processes the signal,
and outputs a 4-20 mA dc current that is proportional to a user specified
range such as 0-250 Deg. F. Combining transmitters with an
existing PLC or DCS system results in a high density, low cost monitoring system. When specified with the alarm feature
(CMCP-560A), the unit functions
as a complete single channel monitor that includes alert and danger alarms,
and output relays.
Buffered Output:
A BNC connector mounted on the front
of the unit provides access to the buffered transducer output signal. Portable test equipment or analyzers like SKF-CM's
MicrologTM can be connected to this output without disturbing
other system outputs.
Fault Detection:
On board fault detection circuitry
continuously monitors the transducer for normal operation. If a fault
occurs, the output current is reduced to 2 mA to indicate the fault to the
readout system. A red LED on the front of the unit is turned on to provide a
local indication of the fault.
Displays And Assemblies:
Various display options, NEMA
and explosion-proof enclosures, and assembled multi-channel systems are
available. Consult your sales representative.
Monitoring Systems
Electrical Specifications:
-
Power: +24 Vdc @ 45 mA max.
(30 mA typical at 2
full scale output). Reverse polarity and transient protection
included.
-
Buffered Output: BNC Connector
-
Accuracy: 5.0 % of Full Scale Range.
-
Output: 4-20 mA proportional to the full scale range.
-
Maximum Load: 600 Ohms Resistive.
-
Case: Isolated.
Environmental Specifications:
-
Operating Temp.: -20oC to +80oC
(-4oF to +176oF).
-
Storage Temp.: -55oC to +125oC (-67oF
to +257oF).
-
Relative Humidity: 0 - 95% Non-Condensing.
Mounting:
32 mm (G style) or 35 mm (T style) DIN Rail.
Ordering Example:
To order a standard
isolated RTD temperature transmitter that accepts input from a 100 Ohm
platinum RTD, with a Full Scale of 0-250 Deg. F,
specify Part Number: CMCP-560-100P-01.
NOTES:
1.The Full Scale option
specified at order entry is used by the factory for initial calibration.
However, several other ranges can be jumper selected in the field.
2 .Transducer
and Full Scale options not listed in the above table are available.
Contact your sales representative.
Ordering
Information:
Isolated RTD Temperature Monitor/Transmitter CMCP-560
CMCP-560(X)-(aaaa)-(bb)
CMCP-560 Isolated RTD Temperature
Transmitter
CMCP-560A Isolated RTD Temperature Monitor
(aaaa) Input
100P, 100 Ohm Platinum RTD
(bb) Full Scale
01, 0-250 oF
02, 0-350 oF
03, 0-500 oF
51, 0-120 oC
52, 0-175 oC
53, 0-260 oC
|
|