CMCP-560 Isolated RTD Temperature Transmitter


CMCP-560 Isolated RTD Temperature Transmitter

Features:

  • Low Cost

  • Small Size

  • DIN Rail Mount

  • 4-20 mA Output

  • Fault Detection

  • Buffered Transducer Output

Approved


Description:
The CMCP-560 Isolated RTD Temperature transmitters are compatible with isolated RTD inputs, they provide a 4-20 mA output proportional to the overall measurement. Each unit provides power for the associated transducer, processes the signal, and outputs a 4-20 mA dc current that is proportional to a user specified range such as 0-250 Deg. F. Combining transmitters with an existing PLC or DCS system results in a high density, low cost monitoring system. When specified with the alarm feature (CMCP-560A), the unit functions as a complete single channel monitor that includes alert and danger alarms, and output relays.

 

Buffered Output:
A BNC connector mounted on the front of the unit provides access to the buffered transducer output signal. Portable test equipment or analyzers like SKF-CM's MicrologTM can be connected to this output without disturbing other system outputs.

 

Fault Detection:
On board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to 2 mA to indicate the fault to the readout system. A red LED on the front of the unit is turned on to provide a local indication of the fault.

 

Displays And Assemblies:
Various display options, NEMA and explosion-proof enclosures, and assembled multi-channel systems are available. Consult your sales representative.

Monitoring Systems

 

Electrical Specifications:

  • Power: +24 Vdc @ 45 mA max. (30 mA typical at 2 full scale output). Reverse polarity and transient protection   included.

  • Buffered Output: BNC Connector

  • Accuracy: 5.0 % of Full Scale Range.

  • Output: 4-20 mA proportional to the full scale range.

  • Maximum Load: 600 Ohms Resistive.

  • Case: Isolated.

 

Environmental Specifications:

  • Operating Temp.: -20oC to +80oC (-4oF to +176oF).

  • Storage Temp.: -55oC to +125oC (-67oF to +257oF).

  • Relative Humidity: 0 - 95% Non-Condensing.

Mounting:
32 mm (G style) or 35 mm (T style) DIN Rail.

 

Ordering Example:

To order a standard isolated RTD temperature transmitter that accepts input from a 100 Ohm platinum RTD, with a Full Scale of 0-250 Deg. F, specify Part Number: CMCP-560-100P-01.

NOTES:

1.The Full Scale option specified at order entry is used by the factory for initial calibration. However, several other ranges can be jumper selected in the field.

2.Transducer and Full Scale options not listed in the above table are available. Contact your sales representative.


Ordering Information:

Isolated RTD Temperature Monitor/Transmitter CMCP-560
CMCP-560(X)-(aaaa)-(bb)

CMCP-560 Isolated RTD Temperature Transmitter
CMCP-560A Isolated RTD Temperature Monitor

(aaaa) Input
100P, 100 Ohm Platinum RTD
(bb) Full Scale
01, 0-250 oF
02, 0-350 oF
03, 0-500 oF

51, 0-120 oC

52, 0-175 oC

53, 0-260 oC